High Power Detector
Standa
High Power Detector
High Power Detector
( 0 )
 
Advanced products search 
Products
 
Opto-Mechanical Products
Optical Tables
Brackets & Rails
Base Mounts & Accessories
Optical Mounts
Optical Positioners
Base Positioners
Translation & Rotation Stages
Motorized Positioners & Controllers
Direct-Drive & BLDC Motor Stages (Actuators)
Gantry & Portal Granite Systems
Fine Adjustment Screws
Opto-Mechanics
Custom Engineering
Vacuum Compatible Products
Optics, Lasers & Measurement
Optics
Lasers & Laser Accessories
Light Test & Measurement Instruments
Spectroscopic Instruments
Spectrographs & Monochromators
Product Index
Product Search
New Products
My Links
My WishList
Catalog Request
Videos
Sale
My Account
User Name / email:
Password:
Remember login
Restore password | Register account
 
My WishList
There are no products in the WishList.
Submit Inquiry
edit WishList
help
 
STANDA in Lithuania
STANDA P.BOX 2684 , 03001 Vilnius 9 P.O., Lithuania
Phone +370 5 2651474, Fax +370 5 2651483
E-mail: sales@standa.LT
   
Standa in the World
   
 
11SUPER-HP - High Power Detector
High Power Detector
Zoom in
Printable version
The Highest Power Handling
Custom models handle up to 25 000 W of continuous power. Higher powers are available upon request
Stable Reading
Less sensitive to variations in water cooling temperature than any other high power water-cooled meter on the market
Infinite Customization Capabilities
1. Choose YOUR size
2. Choose YOUR maximum power
3. We will customize one just for you!
Compact and Light Weight
Lighter and more compact than any other high power detector on the market, thanks to our unique design
Direct USB Connection to a PC
Each head comes with both a DB-15 connector (for use with a Standa monitor) and a USB2.0 output for direct connection to a PC. Other connectors available upon request
 
 
Model (custom built) 11HP280/100A-10KW-HD 11HP210A-25KW-HD
Max average power (continuous / 5 minute) 10 000 W / 10 000 W 25 000 W / 25 000 W
Effective aperture 280 x 100 mm 210 x 210 mm
Cooling method Water-Cooled Water-Cooled
MEASUREMENT CAPABILITY
Spectral Range 0.19 - 20 µm 0.19 - 20 µm
Noise Equivalent Power 1 ±10 W ±10 W
Minimum Average Power 2 300 W 300 W
Rise Time (nominal) 20 sec 25 sec
Sensitivity (typ into 100 kΩ load) 0.2 mV/W 0.08 mV/W
Calibration Uncertainty
@ 1064 nm ±5 % ±5 %
@ 810 nm ±6 % ±6 %
Repeatability ±2 % ±2 %
Linearity with Power ±2 % ±2 %
Linearity vs Beam Diameter 3 ±2 % ±2 %
DAMAGE THRESHOLDS
Maximum Average Power Density 4
10 kW 2.5 kW/cm 2.5 kW/cm2
25 kW --- 0.25 kW/cm2
PHYSICAL CHARACTERISTICS
Effective Aperture 280 x 100 mm 210 x 210 mm
Absorber (High Damage Threshold) HD HD
Required Cooling Flow (6 - 10) LPM < ±1 LPM/min 5 (12 - 15) LPM < ±1 LPM/min 5
Temperature of Cooling Water (15 - 25) °C < ±1°C/min 5 (15 - 25) °C < ±1°C/min 5
Output Connectors DB-15 cable & USB port DB-15 cable & USB port
PCB Electrical Supply Through USB or Standa monitors Through USB or Standa monitors
Maximum Output Signal 2 V 2 V
Dimensions 152H x 305W x 75D mm 229H x 229W x 80D mm
Weight (head only) 11 kg 16 kg

1. Nominal value, actual value depends on electrical noise in the measurement system.
2. For lower powers, call your Standa representative.
3. For a centered beam with size from 20% to 80% of the total aperture.
4. At 1064 nm, 1.07-1.08 µm and 10.6 µm.
5. Average period > 1 min.

Compatible Monitors:


11MAESTRO

11UNO

11TUNER

11M-LINK

11P-Link

11S-LINK

 
Ordering Information
Model  
11HP210A-25KW-HD
11HP280/100A-10KW-HD
 
 
 
 