MICROLASER |
STA-01SH-OEMAR |
|
SPECIFICATIONS |
Parameter |
Value |
Notes |
Operating mode |
pulsed |
Repetitively passively Q-switched |
Wavelength [nm] |
532 |
Second Harmonic of Nd:YAG 1064 nm (4F3/2 - > 4I11/2 transition) |
|
|
|
Average Power [mW] |
≥23 |
Measured at 100 kHz. |
Pulse Repetition Rate PRR [kHz] |
100 |
Laser operating PRR |
Pulse Duration FWHM [ps] |
450 ± 50 |
Measured at 532 nm |
Pulse Timing Jitter [ns] |
<300 |
Expected to be less than 50 ns |
Average Power Stability [%] |
RMS |
≤ 1 |
Over 8 hours, after 30 min warm up.
Room conditions, Tamb = 23 ± 2 C |
PTP |
≤ 10 |
Spatial Mode |
TEM00 |
|
Half-angle beam
divergence 1/e2 [µm] |
|
Available upon request |
Beam Diameter 1/e2 [mm] |
0.80-1.20 |
|
M2 |
≤1.3 |
|
Polarization |
Linear, better 100:1 |
|
Ellipticity [%] |
≤20 |
|
Pulse Spectral Structure |
SLM |
|
|
Interfaces |
USB,
External Triggering (TTL rising edge) |
|
Laser Head Dimensions
Height x Length x Width [mm] |
99 x Ø 24 |
51 x 99 x 51(including Heat sink) |
Laser Controller Dimensions
Height x Length x Width [mm] |
51 x 179 x 150 |
|
Laser Controller Weight [kg] |
≈ 0.8 - 0.9 |
|
|
Laser Head Cooling |
Provided |
Heat Sink (refer to environment and mounting requirements) |
Laser Controller Cooling |
Not provided |
(refer to environment and mounting requirements) |
Electrical specifications: |
Input Power Voltage |
5VDC ± 0.25V |
|
Current |
<8A |
Typical < 6 A (at room temperature),
cold start < 8 A |
Operating environment requirements: |
Operating Conditions |
Tamb = 23 ± 2 C, humidity 45%-60% |
Non-condensing environment. |
Temperature of baseplate for Laser Head mounting |
<30 |
recommended |
Temperature of baseplate for Controller mounting |
<30 |
recommended |
|
|
|
Warranty |
5000 hours or 12 months. |
Whatever occurs first. |
Specifications are subject to change without notice
Parameters are measured at 100 kHz
[1-(minor axis/major axis)] x 100%, zero for perfect round beam.
Overall system dimensions are shown in the drawings below.